Calculations are presented for electromagnetic power deposition (specific absorption rates, or SARs) in an anatomically realistic model of the human torso for spatially varying leakage magnetic fields due to a 450 kHz RF induction heater. A previously described impedance method that neglects the effects of the operator's body on the source, because of weak coupling, is used for the calculations. SARs on the order of a few mu W/Kg are found for magnetic fields on the order of 1.8 A/m at the central plane of the model. This implies that fairly low SARs result from leakage magnetic fields on the order of 1-20 A/m that are typical of RF induction heaters.>