The effect of lamination process on the performance of Metglas/ Pb(Zr,Ti)O 3 ‐based composite magnetoelectric ( ME ) sensors has been studied. Improved sensor processing can lead to higher coupling between the magnetostrictive and piezoelectric phases. A higher coupling factor results in higher magnetic field sensitivity and lower equivalent magnetic noise floors. Spin‐coat/vacuum‐bag application and cure of interfacial epoxy, in addition to the use of Metglas foils with enhanced magnetostriction (λ = 42 ppm), has led to an increase in the ME coefficient from 6 to 21.6 V/cm·Oe, and a decrease in the 1 Hz equivalent magnetic noise from 2 × 10 −10 to 4 × 10 −11 T/√Hz.
No takes yet. Share an insight, caveat, or question.
Li et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: