Key result
Auditory P300 event-related potentials significantly detected minimal hepatic encephalopathy among cirrhotic patients with an AUROC of 0.725, whereas visual P300 was not effective.
Why the study?
Current psychometric tests for minimal hepatic encephalopathy have low sensitivity, specificity, and accuracy, and only auditory P300 event-related potentials had been used previously.
Does auditory or visual P300 event-related potential accurately detect minimal hepatic encephalopathy in patients with liver cirrhosis?
Cross-Sectional (n=84)
No
Does auditory or visual P300 event-related potential accurately detect minimal hepatic encephalopathy in patients with liver cirrhosis?
Auditory P300 event-related potentials, but not visual P300, are useful for detecting minimal hepatic encephalopathy in patients with liver cirrhosis.
Answers are grounded in this paper and cite their sources.
Auditory P300 may aid MHE detection; leaves open validation before clinical adoption.
INTRODUCTION: the diagnosis of minimal hepatic encephalopathy (MHE) requires psychometric tests, although new methods are needed since their sensitivity, specificity, and accuracy are low. The P300 event-related potential (ERP) is obtained by auditory and visual stimuli, although only the auditory P300 has been used to detect MHE. This study aimed to compare the diagnostic features of auditory and visual P300 to detect MHE. MATERIALS AND METHODS: sixty patients with liver cirrhosis and thirty-five healthy controls completed the Psychometric Hepatic Encephalopathy Score (PHES), the critical flicker frequency (CFF), and auditory and visual P300 tests. MHE was diagnosed if PHES and CFF scores were abnormal. RESULTS: fifty-three cirrhotic patients (aged 54.5 ± 8.6 years) completed all tests. Abnormal scores were obtained for PHES (49.1 %) and CFF (67.9 %). The proportion of MHE was 21.4 %. The area under the receiver operating (ROC) curves (AUROC) for auditory P300 was better than for visual P300 for distinguishing MHE from controls (AUROC: 0.792 vs 0.725; p < 0.005 for both; accuracy: 73.8 % vs 70.2 %; sensitivity: 72.2 % for both; specificity: 74.2 vs 69.7, respectively). Among cirrhotic patients, only auditory P300 was useful to detect MHE (AUROC: 0.723; p < 0.05; 77.4 % accuracy; 61.1 % sensitivity, and 81.8 % specificity). CONCLUSIONS: auditory P300 sensitivity, specificity, and accuracy were similar to those of CFF. Our results showed that only auditory P300 is useful to differentiate patients with MHE, although both modalities, auditory and visual, differentiated patients with cirrhosis from controls. Thus, we consider that visual P300 is not suitable for detecting MHE.
No takes yet. Share an insight, caveat, or question.
Vargas et al. (2021) conducted a cross-sectional in Minimal hepatic encephalopathy (n=84). Auditory P300 event-related potentials vs. Visual P300 event-related potentials was evaluated on Diagnostic accuracy (AUROC) for detecting minimal hepatic encephalopathy among cirrhotic patients (AUROC 0.725, 95% CI 0.574-0.875, p=0.008). Auditory P300 event-related potentials significantly detected minimal hepatic encephalopathy among cirrhotic patients with an AUROC of 0.725, whereas visual P300 was not effective.