Why the study?
The use of displacement forces to identify hostile landing zones in TEVAR planning is hampered by the need for time-expensive computational fluid dynamics.
Does a fast-approximate computation method accurately quantify endovascular stent graft displacement forces compared to CFD in patients with a bovine aortic arch variant?
Does a fast-approximate computation method accurately quantify endovascular stent graft displacement forces compared to CFD in patients with a bovine aortic arch variant?
A novel fast-approximate computation method accurately and rapidly quantifies stent graft displacement forces in the bovine aortic arch, potentially facilitating preoperative TEVAR planning.
Purpose: Displacement forces ( DFs) identify hostile landing zones for stent graft deployment in thoracic endovascular aortic repair (TEVAR). However, their use in TEVAR planning is hampered by the need for time-expensive computational fluid dynamics (CFD). We propose a novel fast-approximate computation of DFs merely exploiting aortic arch anatomy, as derived from the computed tomography (CT) and a measure of central aortic pressure. Materials and Methods: We tested the fast-approximate approach against CFD gold-standard in 34 subjects with the “bovine” aortic arch variant. For each dataset, a 3-dimensional (3D) model of the aortic arch lumen was reconstructed from computed tomography angiography and CFD then employed to compute DFs within the aortic proximal landing zones. To quantify fast-approximate DFs, the wall shear stress contribution to the DF was neglected and blood pressure space-distribution was averaged on the entire aortic wall to reliably approximate the patient-specific central blood pressure. Also, DF values were normalized on the corresponding proximal landing zone area to obtain the equivalent surface traction ( EST). Results: Fast-approximate approach consistently reflected (r 2 =0.99, p<0.0001) the DF pattern obtained by CFD, with a −1.1% and 0.7° bias in DFs magnitude and orientation, respectively. The normalized EST progressively increased (p<0.0001) from zone 0 to zone 3 regardless of the type of arch, with proximal landing zone 3 showing significantly greater forces than zone 2 (p<0.0001). Upon DF normalization to the corresponding aortic surface, fast-approximate EST was decoupled in blood pressure and a dimensionless shape vector (S) reflecting aortic arch morphology. S showed a zone-specific pattern of orientation and proved a valid biomechanical blueprint of DF impact on the thoracic aortic wall. Conclusion: Requiring only a few seconds and quantifying clinically relevant biomechanical parameters of proximal landing zones for arch TEVAR, our method suits the real preoperative decision-making process. It paves the way toward analyzing large population of patients and hence to define threshold values for a future patient-specific preoperative TEVAR planning.
No takes yet. Share an insight, caveat, or question.
Sturla et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: