We demonstrate hybrid femtosecond/picosecond (fs/ps) coherent anti-Stokes Raman scattering for high-speed thermometry in unsteady high-temperature flames, including successful comparisons with a time- and frequency-resolved theoretical model. After excitation of the N(2) vibrational manifold with 100 fs broadband pump and Stokes beams, the Raman coherence is probed using a frequency-narrowed 2.5 ps probe beam that is time delayed to suppress the nonresonant background by 2 orders of magnitude. Experimental spectra were obtained at 500 Hz in steady and pulsed H(2)-air flames and exhibit a temperature precision of 2.2% and an accuracy of 3.3% up to 2400 K. Strategies for real-time gas-phase thermometry in high-temperature flames are also discussed, along with implications for kilohertz-rate measurements in practical combustion systems.
No takes yet. Share an insight, caveat, or question.
Miller et al. (2010) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: