A Helmholtz resonator attached to a nonresonant photoacoustic cell enhances the responsivity to trace gas absorption by as much as a factor of 15.3. A simple system model based on a lumped parameter approach predicts the experimentally determined resonance frequency f(0) within 6% for all five resonator volumes tried and gives a pressure amplitude response at resonance proportional to f(0)(-5/2), which is the approximate experimental dependence. Optimization of response based on the model shows a pressure amplitude dependence on a(1/2), the square root of the radius of the cylindrical tube connecting the cell and the resonator.
No takes yet. Share an insight, caveat, or question.
McClenny et al. (1981) studied this question.