Key result
The proposed deep learning-based method using Korotkoff sounds achieved precise blood pressure measurements with a mean systolic error of 0.2 ± 3.1 mmHg and diastolic error of 0.7 ± 2.5 mmHg.
Why the study?
Existing methods using Korotkoff sounds are vulnerable to measurement conditions and external noise because blood pressure is determined based on sound signal threshold values.
Does a probability-based CNN model using Korotkoff sounds improve the accuracy of automatic non-invasive blood pressure measurement compared to a baseline classification CNN?
Does a probability-based CNN model using Korotkoff sounds improve the accuracy of automatic non-invasive blood pressure measurement compared to a baseline classification CNN?
A novel deep learning method outputting probability values for Korotkoff sounds provides more accurate and robust non-invasive blood pressure measurements than traditional threshold-based or binary classification CNN methods.
This paper proposes a method that automatically measures non-invasive blood pressure (BP) based on an auscultatory approach using Korotkoff sounds (K-sounds). There have been methods utilizing K-sounds that were more accurate in general than those using cuff pressure signals only under well-controlled environments, but most were vulnerable to the measurement conditions and to external noise because blood pressure is simply determined based on threshold values in the sound signal. The proposed method enables robust and precise BP measurements by evaluating the probability that each sound pulse is an audible K-sound based on a deep learning using a convolutional neural network (CNN). Instead of classifying sound pulses into two categories, audible K-sounds and others, the proposed CNN model outputs probability values. These values in a Korotkoff cycle are arranged in time order, and the blood pressure is determined. The proposed method was tested with a dataset acquired in practice that occasionally contains considerable noise, which can degrade the performance of the threshold-based methods. The results demonstrate that the proposed method outperforms a previously reported CNN-based classification method using K-sounds. With larger amounts of various types of data, the proposed method can potentially achieve more precise and robust results.
No takes yet. Share an insight, caveat, or question.
Il Doh (2021) studied Healthy subjects (n=43). Deep learning-based automatic non-invasive measurement of blood pressure using Korotkoff sounds vs. Baseline CNN method was evaluated on Mean error of Systolic Blood Pressure (SBP) compared to auscultatory method (mmHg). The proposed deep learning-based method using Korotkoff sounds achieved precise blood pressure measurements with a mean systolic error of 0.2 ± 3.1 mmHg and diastolic error of 0.7 ± 2.5 mmHg.