Direct density measurements were made from shock-loaded aluminum and copper samples by combining plate-impact experiments with proton radiography at the Los Alamos Neutron Science Center. Flyer plates were accelerated using a 40 mm bore powder gun to create a shock wave in a sample. The sample material was then interrogated in real time using the proton radiography facility. The increase in density behind the shock front causes a measurable change in the transmission of protons through the sample, which can then be quantified as a density value in the material. Hugoniot values were calculated using more traditional techniques to evaluate the accuracy of the radiographically obtained density measurements.
No takes yet. Share an insight, caveat, or question.
Rigg et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: