Answers are grounded in this paper and cite their sources.
The critical current ( I c ) of dense Bi 2 Sr 2 CaCu 2 O 8+x (Bi-2212) round wires with Ag-alloy matrices was measured as a function of axial applied strain ( ), to determine whether the behavior is improved in comparison to wires with a large (30–50%) void fraction in the Bi-2212 filaments. Wires were reacted at approximately under a 1% O 2 in Ar gas mixture at 100 bar pressure to densify the Bi-2212 fraction during the partial melt reaction. After measurement of the I c at 4.2 K and 5 T at Florida State University, wire sections were sent to Lawrence Berkeley National Laboratory where was measured at 4.2 K at 5 and 15 T using a U-shaped bending spring. We found that has a 0.3% wide linear reversible strain range. An unexpected result is that the width of this reversible range seems comparable to that found for porous samples reacted at only 1 bar, apparently negating an earlier plausible supposition that fuller density samples would be more resilient.
No takes yet. Share an insight, caveat, or question.
Godeke et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: