A gas chromatography/mass spectrometry method for 3-MCPD in foods and food ingredients was modified for the determination of 1,3-DCP in soy and related sauces. The method was validated by using a blank soy sauce. The detection limit, quantitation limit and recoveries were determined, and identities were confirmed by mass spectrometry on the basis of analyses of test portions spiked with 1,3-DCP at 10, 25, 50 and 100 ng g(-1). The spiked test portions were quantitated by using an internal standard calibration curve. For the spiked test portions, the mean internal standard-corrected recovery for 1,3-DCP was 100% with a relative standard deviation of 1.32%. The limits of detection and quantitation were determined as 0.055 and 0.185 ng g(-1), respectively. The method also was compared with a headspace GC/MS method recently developed by the UK's Central Science Laboratory. Results from the method comparison showed that the recoveries for the spiked test portions, as well as the amounts of 1,3-DCP found in the retail products, were comparable.
No takes yet. Share an insight, caveat, or question.
Nyman et al. (2003) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: