A nondestructive and sensitive monitor consisting of photocathode wire grids arranged in an XY configuration for measuring the spatial profile, divergence, and intensity of pulsed UV, x-ray, and charged particle beams is described. The monitor has been used to measure laser beams at wavelengths λ=213−532nm, and antiproton, proton, H− ions, and electron beams of energies E=50eV to 5 MeV.
No takes yet. Share an insight, caveat, or question.
M. Hori (2005) studied this question.