Why the study?
Does remote magnetic navigation reduce myocardial injury markers compared to manual catheters in patients undergoing atrial fibrillation ablation?
Does remote magnetic navigation reduce myocardial injury markers compared to manual catheters in patients undergoing atrial fibrillation ablation?
Remote magnetic catheters may create more discrete ablation lesions with less time-corrected myocardial enzyme release compared to manual catheters, without compromising clinical success rates.
Answers are grounded in this paper and cite their sources.
Remote magnetic navigation was associated with lower TnT release; hypothesis-generating for reduced injury without affecting AF ablation success.
BACKGROUND: A remote magnetic navigation (MN) system is available for radiofrequency ablation of atrial fibrillation (AF), challenging the conventional manual ablation technique. The myocardial markers were measured to compare the effects of the two types of MN catheters with those of a manual-irrigated catheter in AF ablation. METHODS: AF patients underwent an ablation procedure using either a conventional manual-irrigated catheter (CIR, n = 65) or an MN system utilizing either an irrigated (RMI, n = 23) or non-irrigated catheter (RMN, n = 26). Levels of troponin T (TnT) and the cardiac isoform of creatin kinase (CKMB) were measured before and after ablation. RESULTS: Mean procedure times and total ablation times were longer employing the remote magnetic system. In all groups, there were pronounced increases in markers of myocardial injury after ablation, demonstrating a significant correlation between total ablation time and post-ablation levels of TnT and CKMB (CIR r = 0.61 and 0.53, p < 0.001; RMI r = 0.74 and 0.73, p < 0.001; and RMN r = 0.51 and 0.59, p < 0.01). Time-corrected release of TnT was significantly higher in the CIR group than in the other groups. Of the patients, 59.6% were free from AF at follow-up (12.2 ± 5.4 months) and there were no differences in success rate between the three groups. CONCLUSIONS: Remote magnetic catheters may create more discrete and predictable ablation lesions measured by myocardial enzymes and may require longer total ablation time to reach the procedural endpoints. Remote magnetic non-irrigated catheters do not appear to be inferior to magnetic irrigated catheters in terms of myocardial enzyme release and clinical outcome.
No takes yet. Share an insight, caveat, or question.
Solheim et al. (2011) studied this question.