The aim of this paper is to study the effects of the magnitude and direction of air flow rate on the characteristics of the corona discharge generated in a wire-duct reactor. Two air flow directions were attempted: one parallel to, and the other normal to the discharge wire in the reactor. The corona current-voltage characteristics correlative with ozone generation were studied under different modes of applied voltage. The results have shown that dc and ac corona current-voltage characteristics depend significantly on the magnitude of the air flow rate in the reactor, whatever the direction of the air flow. The ozone concentration generated by either dc, ac or pulsed coronas with parallel flow is higher than that generated with normal flow with the same discharge conditions. The ozone concentration generated by pulsed coronas is higher than that generated by either dc or ac coronas with the same discharge conditions irrespective of the polarity of the pulsed corona.