A prototype multimode fiber-based Fabry-Perot interferometric pressure probe utilizing a corrugated diaphragm with built-in temperature compensation, with signal recovery by coherence reading, has been constructed and demonstrated. A separate fiber-optic-based temperature sensor was incorporated into the pressure sensor to permit the pressure measurement to be corrected for the temperature dependence of the pressure probe. A measurement range to resolution of 3.6 × 10(4) - 1 and an overall measurement accuracy of ±0.15% have been achieved. This system represents a practical approach for industrial use.
No takes yet. Share an insight, caveat, or question.
Rao et al. (1993) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: