Key result
Limited bedside transthoracic echocardiography successfully detected a previously unknown left ventricular outflow tract obstruction in a young patient presenting for elective hand surgery.
Case Report (n=1)
Bedside TTE is a useful assessment tool for anesthesiologists to evaluate incidental murmurs in the perioperative setting.
Bedside TTE may aid perioperative murmur evaluation; single case leaves open need for prospective validation before wider use.
We present a case of left ventricular outflow tract (LVOT) obstruction detected by limited bedside transthoracic echocardiography (TTE). This involved a young and otherwise healthy patient presenting for elective hand surgery with a previously undetected cardiac murmur. It highlights the utility of bedside TTE as an assessment tool and shows the importance of anesthesiologists as perioperative physicians.
No takes yet. Share an insight, caveat, or question.
Davidson et al. (2019) conducted a case report in Left ventricular outflow tract (LVOT) obstruction (n=1). Limited bedside transthoracic echocardiography (TTE) was evaluated on Detection of LVOT obstruction. Limited bedside transthoracic echocardiography successfully detected a previously unknown left ventricular outflow tract obstruction in a young patient presenting for elective hand surgery.