Key result
The proposed transducer adaptive ultrasound volume reconstruction (TAUVR) method reduced average distance error to 12.67 mm compared to 15.73 mm with the unadapted source model on transabdominal scans.
Why the study?
Deep learning methods for 3D ultrasound volume reconstruction are specific to particular transducers and scanning trajectories, lacking generalization to other image acquisition settings.
A novel domain adaptation strategy for deep learning-based 3D ultrasound volume reconstruction improves accuracy across different transducers without requiring external tracking devices.
May facilitate tracking-free 3D ultrasound reconstruction; leaves open prospective clinical validation in cardiovascular imaging.
Reconstructed 3D ultrasound volume provides more context information compared to a sequence of 2D scanning frames, which is desirable for various clinical applications such as ultrasound-guided prostate biopsy. Nevertheless, 3D volume reconstruction from freehand 2D scans is a very challenging problem, especially without the use of external tracking devices. Recent deep learning based methods demonstrate the potential of directly estimating inter-frame motion between consecutive ultrasound frames. However, such algorithms are specific to particular transducers and scanning trajectories associated with the training data, which may not be generalized to other image acquisition settings. In this paper, we tackle the data acquisition difference as a domain shift problem and propose a novel domain adaptation strategy to adapt deep learning algorithms to data acquired with different transducers. Specifically, feature extractors that generate transducer-invariant features from different datasets are trained by minimizing the discrepancy between deep features of paired samples in a latent space. Our results show that the proposed domain adaptation method can successfully align different feature distributions while preserving the transducer-specific information for universal freehand ultrasound volume reconstruction.
No takes yet. Share an insight, caveat, or question.
Guo et al. (2020) studied Prostate imaging (n=652). Transducer Adaptive Ultrasound Volume Reconstruction (TAUVR) vs. Source model only (no adaptation) was evaluated on Average distance error on target domain (transabdominal scans). The proposed transducer adaptive ultrasound volume reconstruction (TAUVR) method reduced average distance error to 12.67 mm compared to 15.73 mm with the unadapted source model on transabdominal scans.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: