Answers are grounded in this paper and cite their sources.
The performance of a hybrid flow meter for the measurement of oil-water two-phase flow rates is investigated. The hybrid flow meter consists of a venturi meter and an oval gear flow meter. Experimental investigations were undertaken on horizontal pipelines of 15 mm, 25 mm, and 40 mm diameters on an oil-water two-phase flow loop. The total flow rate of the oil-water two-phase flow is in the range of 1.2 ∼ 5.5 m3/h, while the oil volume fraction varies from 0 to 100%. The research verifies that the hybrid flow meter is feasible for oil-water two-phase flow measurement and the accuracy of the hybrid flow meter is satisfactory. Experimental results also indicate that the oil fraction has a significant impact on the selection of the meter coefficient of the venturi and hence the measurement results of density and total mass flow rate.
No takes yet. Share an insight, caveat, or question.
Li et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: