Key result
Balloon valvuloplasty followed by low-dose thrombolysis successfully reduced the mean aortic valve pressure gradient from 45 mmHg to 18 mmHg in a patient with TAVI thrombosis.
Why the study?
Does balloon valvuloplasty followed by thrombolysis improve hemodynamics and symptoms in a patient with TAVI thrombosis refractory to initial medical therapy?
Case Report (n=1)
No
Does balloon valvuloplasty followed by thrombolysis improve hemodynamics and symptoms in a patient with TAVI thrombosis refractory to initial medical therapy?
Balloon valvuloplasty combined with thrombolytic therapy may serve as a successful rescue strategy for inoperable patients with TAVI thrombosis who fail to respond to initial therapeutic anticoagulation.
Answers are grounded in this paper and cite their sources.
Suggests a potential rescue strategy for inoperable TAVI thrombosis refractory to anticoagulation; leaves.
Data on the incidence, characteristics, and treatment of thrombosis of a transcatheter aortic valve implantation (TAVI) implant are scarce. We report a challenging case of a TAVI thrombosis occurring 6 months after the procedure. Initial anticoagulation using low-molecular-weight heparin followed by thrombolytic therapy failed to both relieve symptoms and alleviate thrombosis. However, the condition of the patient deteriorated rapidly, necessitating the use of balloon valvuloplasty followed by low-dose thrombolysis. The uniqueness of the case can be summarized as follows: (1) first report of balloon valvuloplasty to manage a case of TAVI thrombosis; (2) thrombolytic therapy after balloon valvuloplasty was successful to further reduce gradient from valve thrombosis.
No takes yet. Share an insight, caveat, or question.
Sharif-Yakan et al. (2017) conducted a case report in Transcatheter aortic valve thrombosis (n=1). Balloon valvuloplasty and low-dose thrombolysis was evaluated on Mean aortic valve pressure gradient. Balloon valvuloplasty followed by low-dose thrombolysis successfully reduced the mean aortic valve pressure gradient from 45 mmHg to 18 mmHg in a patient with TAVI thrombosis.
Synapse has enriched 10 related papers. Consider them for comparative context: