The effective refractive index as a function of vacuum wavelength is approximated by Lagrange interpolation polynomials. The rms value of the chromatic dispersion is then calculated analytically. Itis demonstrated that use of fourth-degree polynomials is far more efficient than the use of second-degree polynomials. The rms value of the chromatic dispersion over the wavelength range (1.25 µm, 1.60 µm) is calculated and minimized for step-index fibers, triangular index fibers, and α-power fibers. The full vector solution of Maxwell's equations is used. The error induced by the approximate refractive-indexmodel is found to be negligible at the point of minimum dispersion.
No takes yet. Share an insight, caveat, or question.
R. Lundin (1993) studied this question.