A combined experimental and theoretical study was performed to understand how the pore size of packing materials with pores 60-300 Å in size affects the separation of 5-50-mer oligonucleotides. For this purpose, we developed a model in which the solutes were described as thin rods to estimate the accessible surface area of the solute as a function of the pore size and solute size. First, an analytical investigation was conducted in which we found that the selectivity increased by a factor of 2.5 when separating 5- and 15-mer oligonucleotides using packing with 300 Å rather than 100 Å pores. We complemented the analytical investigation by theoretically demonstrating how the selectivity is dependent on the column's accessible surface area as a function of solute size. In the preparative investigation, we determined adsorption isotherms for oligonucleotides using the inverse method for separations of a 9- and a 10-mer. We found that preparative columns with a 60 Å-pore-size packing material provided a 10% increase in productivity as compared with a 300 Å packing material, although the surface area of the 60 Å packing is as much as five time larger.
No takes yet. Share an insight, caveat, or question.
Bagge et al. (2020) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: