Modeling the ultrasound generated by a laser source is critical for using noncontact laser-generated ultrasonic systems for the characterization of material properties. In this work, a laser line source was modeled and verified experimentally by measuring the ultrasonic shear wave signal generated in aluminum with a broadband laser generation/electromagnetic acoustic transducer (EMAT)-detection system. Results of calculations and experiments show that the amplitude directivity of a laser line source is identical to that of a point source in the plane perpendicular to the line axis while the temporal dependence differs.