Why the study?
Does Palmaz stent placement safely treat intraoperative proximal type I endoleaks in patients with abdominal aortic aneurysms undergoing stent-graft repair?
Does Palmaz stent placement safely treat intraoperative proximal type I endoleaks in patients with abdominal aortic aneurysms undergoing stent-graft repair?
Palmaz stent placement is a feasible and safe treatment for intraoperative proximal type I endoleaks during AAA stent-graft repair, which do not appear to correlate with stent-graft oversizing or neck morphology.
Palmaz stenting may treat proximal type I endoleaks; leaves open predictors of occurrence in observational AAA repair data.
Purpose: To study factors that might contribute to intraoperative proximal type I endoleak and to evaluate the placement of giant Palmaz stents as a therapeutic option. Methods: Thirty-three patients (30 men; median age 72 years, range 50–85) with abdominal aortic aneurysms underwent implantation of fully supported Gianturco Z-stent—based endografts (12 custom-made aortomonoiliac and 21 bifurcated Zenith devices). Ten (30%) patients were treated for intraoperative proximal endoleaks. Stent-graft oversizing and neck angulation, length, and shape were compared between patients with and without leaks. Results: In 9 cases, the endoleaks were successfully treated with intraoperative placement of Palmaz stents without complications. In 1 patient, a leak that was resolved intraoperatively with balloon dilation reappeared 1 month later; a Palmaz stent was deployed successfully. Stent-graft oversizing did not differ significantly between patients who developed proximal endoleaks and those who did not (median 4.0 mm in both groups, p = 0.47). Median neck length was 21.0 mm in patients with endoleak and 28.0 mm in those without (p > 0.99). Median neck angulation was 30° in both groups (p = 0.33), and the presence of a conical aneurysm neck was not significantly different (2/10 versus 6/23, p > 0.99). All aneurysms remained excluded at a median follow-up of 13 months (range 6–24). Conclusions: Stent-graft oversizing and neck morphology (length, angulation, and conical shape) do not seem to correlate with the incidence of proximal type I endoleaks. Palmaz stent placement appears to be a feasible and safe treatment option for this complication.
No takes yet. Share an insight, caveat, or question.
Dias et al. (2001) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: