Key result
Real-time 3D echocardiography demonstrates ~93% feasibility for measuring left atrial volume but yields smaller volumes than 2D.
Why the study?
Left atrial function and volume changes across development are not well characterized in children using real time 3D echocardiography (RT3DE).
How does left atrial volume measured by real time 3D echocardiography change with age in healthy subjects compared to 2D echocardiography?
Cross-Sectional (n=359)
How does left atrial volume measured by real time 3D echocardiography change with age in healthy subjects compared to 2D echocardiography?
RT3DE is a feasible and reproducible method for evaluating left atrial volume from early infancy to adulthood, providing reference values for future studies.
AimsReal time 3D echocardiography (RT3DE) has been applied for the assessment of left atrial (LA) function in patients with adult heart disease; however, LA function is not well known in children. We aimed at determining the normal range of LA volume (LAV) using RT3DE and the feasibility and reproducibility of this method in healthy subjects and at elucidating the developmental changes in the LAV with aging.Methods and ResultsIn this study, 359 healthy people (mean age, 23.9 ± 21.3; range, 0.1–76.4 years) were enrolled. We performed transthoracic RT3DE and measured the maximum and minimum LAV. Simultaneously, we measured the LAV using the 2D biplane Simpson's method. Inter‐observer and intra‐observer variability and the agreement of LAV measurements between RT3DE and 2DE were assessed in a subset of subjects. The RT3DE feasibility for LAV measurement was 93%. Both maximum and minimum LAVs exponentially increased with age and linearly increased with increasing of body surface area (BSA). The LA distensibility, which demonstrates LA reservoir function, decreased with age and BSA. The LAVs measured by RT3DE were significantly smaller than those measured by the 2D biplane Simpson's method. The 3D volumetric method had favorable intra‐observer and inter‐observer agreement.ConclusionThe reference values of LAV from early infancy to adulthood were obtained using RT3DE, which could be useful for future studies in children with congenital heart disease. RT3DE is a reproducible method and a feasible tool for evaluating the LAV in children. LA reservoir function is likely to decrease with age and increasing of body size.
No takes yet. Share an insight, caveat, or question.
Tanaka et al. (2014) conducted a cross-sectional in Healthy (n=359). Real time 3D echocardiography (RT3DE) vs. 2D biplane Simpson's method was evaluated on Maximum and minimum left atrial volume (LAV). Real time 3D echocardiography had 93% feasibility for measuring left atrial volume, yielding significantly smaller volumes compared with the 2D biplane Simpson's method.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: