This paper reports on figure-of-merit (FoM) enhancement techniques for a new class of lithium niobate (LN)-based microelectromechanical systems laterally vibrating resonators (LVRs). A weighted electrode configuration is used to experimentally demonstrate a more than 2× enhancement for the device electromechanical coupling kt2, and an optimized reactive ion etch is used to attain straighter LN sidewalls and subsequently a 3× improvement in quality factor (Q=1300). As a result, the resonators orientated 30 ° to +y in the x-cut plane exhibited a kt2of 21.7%, and a quality factor of 1300, effectively corresponding to an FoM of 280-the highest demonstrated to date for LVRs. These devices are expected to provide an unprecedented and unmatched platform for frequency-agile and adaptive RF filtering technology.
No takes yet. Share an insight, caveat, or question.
Gong et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: