By considering the infrared transmittance model of Zachor as the equation for an elliptic cone, a quadratic generalization is proposed that yields significantly greater computational accuracy. The strong-band parameters are obtained by iterative nonlinear, curve-fitting methods using a digital computer. The remaining parameters are determined with a linear least-squares technique and a weighting function that yields better results than the one adopted by Zachor. The model is applied to CO(2) over intervals of 50 cm(-1) between 550 cm(-1) and 9150 cm(-1) and to water vapor over similar intervals between 1050 cm(-1) and 9950 cm(-1), with mean rms deviations from the original data being 2.30 x 10(-3) and 1.83 x 10(-3), respectively.