A very efficient technique for computing the closed loop performance sensitivities to parameter variations of a dynamic system with a reduced order controller has been developed. The eigensystem of the closed loop system is computed once. With this information, the closed loop filter and state rms responses, and the first and second derivatives of these rms values with respect to given parameters are computed. Detailed numerical examples using the JPL flexible beam and a 55 meter offset fed, wrap-rib antenna are included.
No takes yet. Share an insight, caveat, or question.
D. B. Schaechter (1983) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: