Experimental study demonstrates that excess superplasticizer increases porosity and reduces concrete strength, highlighting 0.8 wt.% superplasticizer and 0.3 vol.% steel fibers as optimal.
This study investigates the effects of low-volume steel microfibers (0–0.4 vol.%) and superplasticizer (SP) dosage (0.8 wt.% and 1.5 wt.%) on the mechanical and durability properties of self-compacting concrete (SCC) for railing structures, with a constant water-binder ratio of 0.28. Fresh (slump flow), mechanical (compressive strength up to 90 days, 28-day flexural strength), durability (drying shrinkage, freeze–thaw resistance after 200 cycles), and microstructural (mercury intrusion porosimetry) properties were evaluated. SP enhances flowability while steel fibers reduce it. All mixtures except that with 0.8% SP and 0.4% fibers meet the workability requirements of Chinese standard JGJ/T 283-2012 for SCC. Compressive and flexural strengths generally increase with fiber content but decrease when the SP dosage rises from 0.8% to 1.5%. Steel fibers effectively reduce drying shrinkage and improve freeze–thaw resistance, as indicated by higher relative dynamic elastic moduli and lower mass loss after 200 cycles. Microstructural analysis reveals that the higher SP dosage (1.5 wt.%) significantly increases porosity, which explains the observed higher shrinkage and lower strength. Considering mechanical properties, durability, and castability, the SCC mixture with 0.3 vol.% steel fibers and 0.8 wt.% SP is recommended for railing structure applications.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: