Answers are grounded in this paper and cite their sources.
We present a detailed report of the method, setup, analysis, and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100% polarized surface muon beam and a segmented, fast-timing plastic scintillator array. The measurement employed two target arrangements: a magnetized ferromagnetic target with a ~4 kG internal magnetic field and a crystal quartz target in a 130 G external magnetic field. Approximately 1.6×10¹² positrons were accumulated and together the data yield a muon lifetime of τ_μ(MuLan)=2196980.3(2.2) ps (1.0 ppm), 30 times more precise than previous generations of lifetime experiments. The lifetime measurement yields the most accurate value of the Fermi constant GF(MuLan)=1.1663787(6)×10^-5 GeV^-2 (0.5 ppm). It also enables new precision studies of weak interactions via lifetime measurements of muonic atoms.
No takes yet. Share an insight, caveat, or question.
Tishchenko et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: