Thin copper foils were irradiated with 650 keV electrons at 10 K in a high-voltage electron microscope (HVEM) to doses φ in the range 2 × 1023 electrons/m2 ≲ φ ≲ 2 × 1025 electrons/m2 and then annealed in situ up to room temperature and outside the HVEM between room temperature and 470 K. During irradiation visible defect clusters were formed only at φ ≳ 2.5 × 1024 electrons/m2. At smaller doses defect clusters became visible after annealing at 50 K. Between 50 K and 120 K further clusters, mainly dislocation loops on {111} planes, appeared. Above 120 K, particularly between 160 K and 300 K, some of the dislocation loops became glissile. They glided out of the specimens or agglomerated to larger clusters of frequently complex shapes. As a consequence, between 160 K and 300 K the cluster density decreased strongly, whereas the mean cluster size increased monotonously through the entire range of annealing temperatures covered. Contrast analyses between 180 K and 400 K revealed that the great majority of the dislocation loops were of interstitial type. At 470 K a new type of small clusters emerged, presumably of vacancy type. These observations are compared with other studies on electron-irradiated copper and with the current models of radiation damage in metals.
No takes yet. Share an insight, caveat, or question.
Jäger et al. (1980) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: