Answers are grounded in this paper and cite their sources.
In this paper, a sensitive-enhanced single-mode fiber—tapered hollow core fiber—single-mode fiber Mach–Zehnder interferometer is demonstrated for refractive index sensing. The sensitivity was improved by forming an up-taper at the two splicing joints and concave cone in hollow core fiber. The up-tapered regions served as a more effective mode splitter/combiner, and the tapered hollow core fiber was used to generate a stronger evanescent field to enhance the interaction of light with the analyte. According to the principles of interference between the cladding and fundamental modes, we performed refractive index measurements. The experiments indicated that the proposed sensor has a high refractive index sensitivity of 214.97 nm/RIU in the refractive index range of 1.333–1.379, with a minimum refractive index measurement resolution of 9.3 × 10−5. In addition, the sensor had a low temperature response of 2.96 pm/°C in the range from 50 to 85°C and a low cross sensitivity of 1.377 × 10−5 RIU/°C. The proposed sensor is attractive for its high refractive index sensitivity, easy fabrication, low cross sensitivity, and good mechanical strength, making it of potential value for refractive index measurements for chemical and biological sensing.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: