Modulation-rate perception was measured for three tasks: a fixed-standard, forced-choice discrimination task with a 500-ms interstimulus interval; a random-standard, forced-choice discrimination task with an 8-s interstimulus interval; and an identification task. Thresholds were obtained for modulation rates from 14-224 Hz using noise carriers bandpass filtered from 500-4000 Hz, 500-1600 Hz, 1700-2800 Hz, and 2900-4000 Hz. The four bands yielded similar results except for modulation rates greater than 100 Hz, where the 500- to 1600-Hz thresholds were higher. Fixed-standard discrimination thresholds were about 3 Hz for modulation rates up to 66 Hz. The increase of thresholds for modulation rates above 66 Hz could be due to temporal resolution limits with a time constant of about 2-3 ms. For modulation rates above 100 Hz, critical-band filtering may further decrease sensitivity for the 500- to 1600-Hz noise band. Resolution in the random-standard discrimination task was similar to that for the identification task. Thresholds were elevated relative to fixed-standard thresholds except at the extremes of the stimulus range. In the random-standard discrimination task, a pronounced criterion bias was present for stimuli near the extremes of the range. Durlach and Braida's model [N. I. Durlach and L. D. Braida, J. Acoust. Soc. Am. 46, 372-383 (1969)] describes the data well and provides quantitative measures for our data in good agreement with those for intensity perception.
No takes yet. Share an insight, caveat, or question.
Thomas E. Hanna (1992) studied this question.