Key result
Lower pulse wave transit time assessed before anaesthesia induction was significantly associated with increased systolic blood pressure variability during induction (r = -0.54).
Why the study?
The study was conducted to establish the relationship between pulse wave transit time before anaesthesia induction and blood pressure variability during anaesthesia induction.
Does pulse wave transit time (PWTT) before anaesthesia induction predict blood pressure variability during induction in patients undergoing elective surgery?
Cohort (n=54)
No
Does pulse wave transit time (PWTT) before anaesthesia induction predict blood pressure variability during induction in patients undergoing elective surgery?
Pulse wave transit time assessed before anaesthesia induction may serve as an effective predictor of haemodynamic fluctuations during induction.
Lower pre-induction PWTT was associated with greater BPV; hypothesis-generating for predictive monitoring, needs prospective validation.
Objective To establish the relationship between pulse wave transit time (PWTT) before anaesthesia induction and blood pressure variability (BPV) during anaesthesia induction. Methods This prospective observational cohort study enrolled consecutive patients that underwent elective surgery. Invasive arterial pressure, electrocardiography, pulse oximetry, heart rate and bispectral index were monitored. PWTT and BPV were measured with special software. Anaesthesia was induced with propofol, sufentanil and rocuronium. Results A total of 54 patients were included in this study. There was no correlation between BPV and the dose of propofol, sufentanil and rocuronium during anaesthesia induction. Bivariate linear regression analysis demonstrated that PWTT ( r = –0.54), age ( r = 0.34) and systolic blood pressure ( r = 0.31) significantly correlated with systolic blood pressure variability (SBPV). Only PWTT ( r = –0.38) was significantly correlated with diastolic blood pressure variability (DBPV). Patients were stratified into high PWTT and low PWTT groups according to the mean PWTT value (96.8 ± 17.2 ms). Compared with the high PWTT group, the SBPV of the low PWTT group increased significantly by 3.4%. The DBPV of the low PWTT group increased significantly by 2.1% compared with the high PWTT group. Conclusions PWTT, assessed before anaesthesia induction, may be an effective predictor of haemodynamic fluctuations during anaesthesia induction.
No takes yet. Share an insight, caveat, or question.
Hu et al. (2021) conducted a cohort in Elective surgery under general anaesthesia (n=54). Pulse wave transit time (PWTT) vs. High PWTT was evaluated on Systolic blood pressure variability (SBPV) during anaesthesia induction (r = -0.54, p=<0.0001). Lower pulse wave transit time assessed before anaesthesia induction was significantly associated with increased systolic blood pressure variability during induction (r = -0.54).