Key result
Entropy and compression of fetal heart rate captured complementary complexity features, with %abSTV correlating with entropies (-0.54 to -0.62) and compression (-0.80 to -0.94).
Observational (n=68)
Entropy and compression capture complementary complexity features in fetal heart rate analysis, with entropy performing better at lower scales and compression at higher scales for distinguishing acidemic fetuses.
Entropy/compression metrics may refine fetal acidemia detection; leaves open prospective validation before clinical adoption.
Entropy and compression have been used to distinguish fetuses at risk of hypoxia from their healthy counterparts through the analysis of Fetal Heart Rate (FHR). Low correlation that was observed between these two approaches suggests that they capture different complexity features. This study aims at characterizing the complexity of FHR features captured by entropy and compression, using as reference international guidelines. Single and multi-scale approaches were considered in the computation of entropy and compression. The following physiologic-based features were considered: FHR baseline; percentage of abnormal long (%abLTV) and short (%abSTV) term variability; average short term variability; and, number of acceleration and decelerations. All of the features were computed on a set of 68 intrapartum FHR tracings, divided as normal, mildly, and moderately-severely acidemic born fetuses. The correlation between entropy/compression features and the physiologic-based features was assessed. There were correlations between compressions and accelerations and decelerations, but neither accelerations nor decelerations were significantly correlated with entropies. The %abSTV was significantly correlated with entropies (ranging between −0.54 and −0.62), and to a higher extent with compression (ranging between −0.80 and −0.94). Distinction between groups was clearer in the lower scales using entropy and in the higher scales using compression. Entropy and compression are complementary complexity measures.
No takes yet. Share an insight, caveat, or question.
Monteiro-Santos et al. (2017) conducted an observational in Fetal hypoxia (n=68). Entropy and compression analysis was evaluated on Correlation between entropy/compression features and physiologic-based features. Entropy and compression of fetal heart rate captured complementary complexity features, with %abSTV correlating with entropies (-0.54 to -0.62) and compression (-0.80 to -0.94).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: