Key result
Domperidone administration in newborn lambs increased the overall loop gain of the respiratory control system more than twofold, from a median of 0.14 to 0.40, indicating an increased propensity for ventilatory instability.
Why the study?
Does intravenous domperidone increase the loop gain of the respiratory control system in anesthetized newborn lambs?
Does intravenous domperidone increase the loop gain of the respiratory control system in anesthetized newborn lambs?
Answers are grounded in this paper and cite their sources.
Model-based analysis of spontaneous breathing can characterize the dynamics of the respiratory control system and predict ventilatory instability.
Cyclic ventilatory instabilities are widely attributed to an increase in the sensitivity or loop gain of the chemoreflex feedback loop controlling ventilation. A major limitation in the conventional characterization of this feedback loop is the need for labor-intensive methodologies. To overcome this limitation, we developed a method based on trivariate autoregressive modeling using ventilation, end-tidal Pco(2) and Po(2); this method provides for estimation of the overall "loop gain" of the respiratory control system and its components, chemoreflex gain and plant gain. Our method was applied to recordings of spontaneous breathing in 15 anesthetized, tracheostomized, newborn lambs before and after administration of domperidone (a dopamine D(2)-receptor antagonist that increases carotid body sensitivity). We quantified the known increase in hypoxic ventilatory sensitivity in response to domperidone; controller gain for O(2) increased from 0.06 (0.03, 0.09) l·min(-1)·mmHg(-1) to 0.09 (0.08, 0.13) l·min(-1)·mmHg(-1); median (interquartile-range). We also report that domperidone increased the loop gain of the control system more than twofold [0.14 (0.12, 0.22) to 0.40 (0.15, 0.57)]. We observed no significant changes in CO(2) controller gain, or plant gains for O(2) and CO(2). Furthermore, our estimate of the cycle duration of periodic breathing compared favorably with that observed experimentally [measured: 7.5 (7.2, 9.1) vs. predicted: 7.9 (7.0, 9.2) breaths]. Our results demonstrate that model-based analysis of spontaneous breathing can 1) characterize the dynamics of the respiratory control system, and 2) provide a simple tool for elucidating an individual's propensity for ventilatory instability, in turn allowing potential therapies to be directed at the underlying mechanisms.
No takes yet. Share an insight, caveat, or question.
Nemati et al. (2011) studied Ventilatory stability (n=15). Domperidone vs. Baseline (before administration) was evaluated on Overall loop gain of the respiratory control system (p=<0.005). Domperidone administration in newborn lambs increased the overall loop gain of the respiratory control system more than twofold, from a median of 0.14 to 0.40, indicating an increased propensity for ventilatory instability.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: