This case highlights the risk of life-threatening iliac artery rupture during TAVI and discusses its diagnosis and management.
Alerts to rare iliac rupture in TAVI; single case leaves open optimal prevention strategies.
A 76-year-old man had severe aortic stenosis and underwent elective transcatheter aortic valve implantation (TAVI). Aortic annulus sizing by transthoracic echocardiography (TTE) was 25 mm. Multislice CT showed adequate iliofemoral arteries calibre with no severe calcifications. The procedure took place by right transfemoral access using a percutaneous closure device (ProStar XL Percutaneous Vascular Surgical System; Abbott Vascular, Redwood City, California, USA). A 26 mm balloon-expandable Edwards–Sapien XT valve (Edwards Lifesciences, Irvine, California, USA) was successfully advanced, however, with some resistance at …
No takes yet. Share an insight, caveat, or question.
Dahdouh et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: