An international intercomparison of horn gain and polarization measurements at X-band has previously been completed. There were seven participating laboratories with the National Institute of Standards and Technology serving as the pilot laboratory. Two X-band pyramidal standard gain horns with a nominal gain of 22 dB served as the traveling standards. Quantities measured included on-axis fixed frequency gain at 8, 10, and 12 GHz, swept frequency gain between 8-12 GHz and polarization characteristics at the three fixed frequencies. All laboratories performed the fixed frequency-gain measurements. The swept-frequency and polarization measurements were optional, with four laboratories performing swept-frequency measurements and three laboratories measuring polarization. The results of the gain measurements generally agreed within the reported uncertainties which were of the order of 0.1 dB or less.
No takes yet. Share an insight, caveat, or question.
Stubenrauch et al. (1996) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: