Modern theoretical notations on electrical breakdown in vacuum consider cathode triggering mechanisms to be most responsible on short-pulsed (<1 /spl mu/s) breakdowns while anode mechanisms to be responsible in a part on DC and long-pulsed breakdowns. Following those notations, we tried to reveal conditions at which either mechanism steps aside to another one. The study involved several experimental techniques including the anode-probe surface scanning, pulsed electron-beam surface melting in vacuum for surface cleaning, and intentional dust particle contamination of electrode surfaces. Breakdown tests were performed using a pulser capable of producing 220 kV quasi-square pulses that were adjustable to /spl sim/30 to 80 ns pulse length. Our experiments showed that cathode emission sites are responsible for breakdowns at relatively low hold-off fields. At higher electric fields of up to 1 MV/cm, the anode share in the mechanism of triggering breakdown becomes probably more significant than the cathode mechanism.
No takes yet. Share an insight, caveat, or question.
Batrakov et al. (2006) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: