Answers are grounded in this paper and cite their sources.
A NbTi/Nb/sub 3/Sn superconducting magnet directly cooled by a 4 K cryocooler has been fabricated. It successfully attained a 10 T field at the center of a 100 mm room temperature bore. A 4 K Gifford-McMahon (GM) cryocooler, using Er/sub 3/Ni regenerator, cools the magnet without the use of liquid helium. Bi/sub 2/Sr/sub 2/CaCu/sub 2/O/sub y/ superconducting power leads were adopted to reduce heat input to the 4 K stage. The coil heat is removed through heat conducting copper cylinders. The coil winding is epoxy-impregnated without a bore tube to stabilize the magnet against quenching. Two diode shunt circuits are placed in the cryostat to protect the coils. A fast ramp of 10 T/20 min, was attained by reducing Nb/sub 3/Sn conductor hysteresis loss and by decreasing the contact resistance between the coil and the conduction cylinder.
No takes yet. Share an insight, caveat, or question.
Koyanagi et al. (1996) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: