The present study provides a first attempt to compare the validity of the respiration line length (RLL) and skin resistance response (SRR) amplitude in real-life criminal guilty knowledge tests (GKTs). GKT records of 40 innocent and 40 guilty Ss, for whom actual truth was established by confession, were assessed for their accuracy. When a predefined decision rule was used and inconclusive decisions were excluded, 97.4% of the innocent Ss and 53.3% of the guilty Ss were correctly classified with the SRR measure. For the RLL measure, the respective results were 97.2% and 53.1%. The combination of both measures improved detection of guilty Ss to 75.8% and decreased detection of innocent Ss to 94.1%. The combined measure seems to be a more useful means of identifying guilty suspects than each physiological measure alone. The results elaborate and extend those obtained in a previous field study conducted by Elaad (1990).
No takes yet. Share an insight, caveat, or question.
Elaad et al. (1992) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: