Key result
HMM-propelled actin filament sliding speed increased with surface contact angle (20-80 degrees), correlated with reduced negative charge and different HMM adsorption configurations.
The study elucidates that heavy meromyosin adsorption and motor function depend on surface hydrophobicity and charge, informing fundamental actomyosin studies and nanotechnological applications.
This is the authors' abstract. We don't add key points for this paper.
The in vitro motility assay is valuable for fundamental studies of actomyosin function and has recently been combined with nanostructuring techniques for the development of nanotechnological applications. However, the limited understanding of the interaction mechanisms between myosin motor fragments (heavy meromyosin, HMM) and artificial surfaces hampers the development as well as the interpretation of fundamental studies. Here we elucidate the HMM-surface interaction mechanisms for a range of negatively charged surfaces (silanized glass and SiO2), which is relevant both to nanotechnology and fundamental studies. The results show that the HMM-propelled actin filament sliding speed (after a single injection of HMM, 120 microg/mL) increased with the contact angle of the surfaces (in the range of 20-80 degrees). However, quartz crystal microbalance (QCM) studies suggested a reduction in the adsorption of HMM (with coupled water) under these conditions. This result and actin filament binding data, together with previous measurements of the HMM density (Sundberg, M.; Balaz, M.; Bunk, R.; Rosengren-Holmberg, J. P.; Montelius, L.; Nicholls, I. A.; Omling, P.; Tågerud, S.; Månsson, A. Langmuir 2006, 22, 7302-7312. Balaz, M.; Sundberg, M.; Persson, M.; Kvassman, J.; Månsson, A. Biochemistry 2007, 46, 7233-7251), are consistent with (1) an HMM monolayer and (2) different HMM configurations at different contact angles of the surface. More specifically, the QCM and in vitro motility assay data are consistent with a model where the molecules are adsorbed either via their flexible C-terminal tail part (HMMC) or via their positively charged N-terminal motor domain (HMMN) without other surface contact points. Measurements of zeta potentials suggest that an increased contact angle is correlated with a reduced negative charge of the surfaces. As a consequence, the HMMC configuration would be the dominant configuration at high contact angles but would be supplemented with electrostatically adsorbed HMM molecules (HMMN configuration) at low contact angles. This would explain the higher initial HMM adsorption (from probability arguments) under the latter conditions. Furthermore, because the HMMN mode would have no actin binding it would also account for the lower sliding velocity at low contact angles. The results are compared to previous studies of the microtubule-kinesin system and are also discussed in relation to fundamental studies of actomyosin and nanotechnological developments and applications.
Answers are grounded in this paper and cite their sources.
No clinical implications yet; leaves open surface tuning for actomyosin nanodevices pending in vivo validation.
No takes yet. Share an insight, caveat, or question.
Albet-Torres et al. (2007) studied this question. Heavy meromyosin (HMM) on negatively charged surfaces was evaluated on HMM-propelled actin filament sliding speed and HMM adsorption. HMM-propelled actin filament sliding speed increased with surface contact angle (20-80 degrees), correlated with reduced negative charge and different HMM adsorption configurations.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: