Thermal overload protection techniques commonly use a simplified 1st order thermal model, which does not provide accurate stator winding temperature prediction and causes frequent undesirable stoppage of the motor in the processes. This paper proposes a higher order lumped parameter thermal network model to accurately predict stator winding temperature. First, the comparison of the predicted stator winding temperature from a 1st order thermal model with a higher order thermal model is performed. Second, a comparison between the actual and the predicted stator winding temperature rise is verified for a 20 hp totally enclosed fan-cooled copper rotor induction motor that has no rotor fins on its short-circuit ring to enhance heat dissipation compared with an aluminum rotor induction motor.
No takes yet. Share an insight, caveat, or question.
Ahmed et al. (2017) studied this question.