Key result
The CARES 3.0 automated algorithm for carotid intima-media thickness measurement showed high accuracy, with an average IMT of 0.852 mm compared to 0.872 mm by the expert reader (bias -0.022 mm).
Why the study?
Does the CARES 3.0 automated algorithm accurately measure carotid intima-media thickness compared to an expert reader in patients undergoing carotid ultrasound?
Cross-Sectional (n=250)
Yes
Does the CARES 3.0 automated algorithm accurately measure carotid intima-media thickness compared to an expert reader in patients undergoing carotid ultrasound?
The CARES 3.0 fully automated algorithm provides highly accurate and reproducible carotid intima-media thickness measurements comparable to an expert reader.
Supports automated carotid IMT assessment in research; leaves open clinical adoption pending prospective validation.
OBJECTIVES: In recent years, the use of computer-based techniques has been advocated to improve intima-media thickness (IMT) quantification and its reproducibility. The purpose of this study was to test the diagnostic performance of a new IMT automated algorithm, CARES 3.0, which is a patented class of IMT measurement systems called AtheroEdge (AtheroPoint, LLC, Roseville, CA). METHODS: From 2 different institutions, we analyzed the carotid arteries of 250 patients. The automated CARES 3.0 algorithm was tested versus 2 other automated algorithms, 1 semiautomated algorithm, and a reader reference to assess the IMT measurements. Bland-Altman analysis, regression analysis, and the Student t test were performed. RESULTS: CARES 3.0 showed an IMT measurement bias ± SD of -0.022 ± 0.288 mm compared with the expert reader. The average IMT by CARES 3.0 was 0.852 ± 0.248 mm, and that of the reader was 0.872 ± 0.325 mm. In the Bland-Altman plots, the CARES 3.0 IMT measurements showed accurate values, with about 80% of the images having an IMT measurement bias ranging between -50% and +50%. These values were better than those of the previous CARES releases and the semiautomated algorithm. Regression analysis showed that, among all techniques, the best t value was between CARES 3.0 and the reader. CONCLUSIONS: We have developed an improved fully automated technique for carotid IMT measurement on longitudinal ultrasound images. This new version, called CARES 3.0, consists of a new heuristic for lumen-intima and media-adventitia detection, which showed high accuracy and reproducibility for IMT measurement.
No takes yet. Share an insight, caveat, or question.
Saba et al. (2013) reported a cross-sectional. CARES 3.0 automated algorithm vs. Expert reader reference was evaluated on Intima-media thickness (IMT) measurement (bias -0.022 mm). The CARES 3.0 automated algorithm for carotid intima-media thickness measurement showed high accuracy, with an average IMT of 0.852 mm compared to 0.872 mm by the expert reader (bias -0.022 mm).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: