Answers are grounded in this paper and cite their sources.
This study introduces a new active‐clamped current‐fed push–pull dc–dc converter for renewable energy conversion applications. The proposed converter conserves small input current pulsation, high‐voltage conversion ratio, zero‐voltage switching (ZVS) and zero‐current‐switching operation for primary switches and rectifier diodes, respectively, over a large load range. Also, the additional active clamping circuit serves to suppress the voltage spike across all primary switches, as well as assists in achieving ZVS operation. So, the low‐voltage switches with low on‐state resistance can be adopted. These features can reduce switching loss, voltage stress, transformer turns ratio and diode reverse‐recovery effect. More importantly, similar characteristics can be obtained with minimised switches compared with the reported converters that enable to reduce the cost and improve the reliability. Detailed steady‐state operation, analysis, performance comparison, experimental results and loss breakdown of the proposed converter are fully discussed in this study. Finally, a 520 W prototype verifies the theoretical analysis.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: