Answers are grounded in this paper and cite their sources.
In this work, a CE equipment, online hyphenated to an IT MS analyzer by a linear sheath liquid interface promoting ESI, was used to develop a method for quantitative determination of amino acids. Under appropriate conditions (BGE composition, 0.8% HCOOH, 20% CH3OH; sheath liquid composition, 0.8% HCOOH, 60% methanol; V ESI, +4.50 kV), analytical curves of all amino acids from 3 to 80 mg/L were recorded presenting acceptable linearity (r >0.99). LODs in the range of 16-172 micromol/L were obtained. BSA, a model protein, was submitted to different hydrolysis procedures (classical acid and basic, and catalyzed by the H+ form of a cation exchanger resin) and its amino acid profiles determined. In general, the resin-mediated hydrolysis yields were overall similar or better than those obtained by classical acid or basic hydrolysis. The resulting experimental-to-theoretical BSA concentration ratios served as correction factors for the quantitation of amino acids in Brazil nut resin generated hydrolysates.
No takes yet. Share an insight, caveat, or question.
Simionato et al. (2008) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: