Numerous methods are proposed to quantify antithyroid peroxidase autoantibodies. No standardization exists but most assays use the standard MRC 66/387 with a calibration factor. Costs of the tests vary between the different kits. We evaluated the concordance of eight peroxidase autoantibodies assay kits in two centres, using a panel of sera from 269 subjects: controls (n=100), patients with autoimmune thyroid disease (n=77; Graves' disease, Hashimoto's thyroiditis), patients with non-autoimmune thyroid disease (n=69; nodular goiter, differentiated thyroid carcinoma) and individual sera with thyroglobulin antibodies only (n=23). The concordance between the eight methods was high, ranging from 88.3% to 98.8% with the total panel of sera. The majority of assays demonstrated high diagnostic performance. We encountered some false-positive results at borderline positive levels, and the nonrecognition of some sera by competitive assays.
No takes yet. Share an insight, caveat, or question.
d’Herbomez et al. (2000) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: