This is the authors' abstract. We don't add key points for this paper.
Magnesium hydride (MgH₂) offers high-capacity solid-state hydrogen storage, but it suffers from slow desorption due to its poor thermal conductivity. Here we model an MgH₂ composite containing 8 wt% expanded natural graphite (ENG), which raises the effective conductivity to 4.2 W.m −1 .K −1 . Finite element method (FEM) simulations performed in COMSOL Multiphysics compare a conventional constant radial heat flux with a stepwise ON/OFF (pulsed) regime. A 15-min ON/OFF cycle shortens the desorption time by 25 % from 60 to 45 min, keeps the wall temperature below 661 K, and leaves 3.4 kJ.m −3 of recoverable sensible heat, whereas constant heating leaves none. Raising conductivity above 4.2 W.m −1 .K −1 offers little extra benefit because gas-phase transport and surface kinetics then dominate. Pulsed heating also exploits thermal-conductivity-evolution feedback (TCEF): MgH₂ converts to metallic Mg during each pulse, further boosting conductivity and accelerating subsequent pulses. Heat-flux sequencing, therefore, delivers faster, more energy-efficient hydrogen release without internal heat-exchanger hardware, highlighting a simple path to improved thermal management in MgH₂-based composite storage systems.
No takes yet. Share an insight, caveat, or question.
Lanbaran et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: