Why the study?
Leadless pacemakers overcome lead-related complications, but prospective studies assessing their long-term safety on cardiac structures are lacking.
Does a leadless pacemaker prevent worsening of left ventricular and valve function compared to a conventional pacemaker in patients with an indication for single chamber ventricular pacing?
Does a leadless pacemaker prevent worsening of left ventricular and valve function compared to a conventional pacemaker in patients with an indication for single chamber ventricular pacing?
Leadless pacing is non-inferior to conventional pacing regarding left ventricular systolic function at 12 months, while causing significantly less tricuspid valve dysfunction.
Micra showed comparable LV function decline but less tricuspid regurgitation than conventional pacing; leaves open whether leadless devices reduce valvular risk long-term.
BACKGROUND: Leadless pacemakers (PMs) were recently introduced to overcome lead-related complications. They showed high safety and efficacy profiles. Prospective studies assessing long-term safety on cardiac structures are still missing. OBJECTIVE: The purpose of this study was to compare the mechanical impact of Micra with conventional PM on heart function. METHODS: We conducted a non-inferiority trial in patients with an indication for single chamber ventricular pacing. Patients were 1:1 randomized to undergo implantation of either Micra or conventional monochamber ventricular pacemaker (PM). Patients underwent echocardiography at baseline, 6 and 12 months after implantation. Analysis included left ventricular ejection fraction (LVEF), global longitudinal strain (GLS) and valve function. N-terminal-pro hormone B-type natriuretic peptide (NT-pro-BNP) levels were measured at baseline and 12 months. RESULTS: Fifty-one patients (27 in Micra group and 24 in conventional group) were included. Baseline characteristics were similar for both groups. At 12 months, (1) the left ventricular function as assessed by LVEF and GLS worsened similarly in both groups (∆LVEF -10 ± 7.3% and ∆GLS +5.7 ± 6.4 in Micra group vs. -13.4 ± 9.9% and +5.2 ± 3.2 in conventional group) (p = 0.218 and 0.778, respectively), (2) the severity of tricuspid valve regurgitation was significantly lower with Micra than conventional pacing (p = 0.009) and (3) median NT-pro-BNP was lower in Micra group (970 pg/dL in Micra group versus 1394 pg/dL in conventional group, p = 0.041). CONCLUSION: Micra is non inferior to conventional PMs concerning the evolution of left ventricular function at 12-month follow-up. Our data suggest that Micra has a comparable mechanical impact on the ventricular systolic function but resulted in less valvular dysfunction.
No takes yet. Share an insight, caveat, or question.
Garweg et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: