This paper presents a comparison of three topologies of multilevel inverters applied to drive an induction motor of 500 kVA/4.16 kV rating. The multilevel inverters analyzed are the following: a neutral-point-clamped inverter, a symmetrical cascaded multilevel inverter, and a hybrid asymmetrical cascaded multilevel inverter. The performance indexes used in the comparison are total harmonic distortion, first-order distortion factor, second-order distortion factor, common-mode voltage, semiconductor power loss distribution, and heat-sink volume. The multilevel inverters are designed to present 99% efficiency at the nominal operating point, and the aforementioned performance indexes are compared for distinct values of amplitude modulation depth.
No takes yet. Share an insight, caveat, or question.
Zambra et al. (2010) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: