Using a graphite electrode modified with vaseline and NiO, ranitidine showed a strongly ECL enhancing effect for the weak ECL signal of electrooxidation of luminol. Based on this finding, a more sensitive ECL method for ranitidine was firstly proposed. Under the optimum experimental conditions, the ranitidine hydrochloride concentration in the range of 3.0×10−8–9.0×10−6 mol/L was proportional to the enhancing ECL signal and offered a 9×10−9 mol/L detection limit for ranitidine hydrochloride. At the same time, based on the investigation on this ECL reaction mechanism, a new concept, to improve the suitable ECL reaction micro‐environment with chemically modified electrode technique for the better analytical performances of ECL analysis was also firstly proposed.