Key result
The APtrans-CNN framework effectively denoised highly corrupted ECG signals, increasing the signal-to-noise ratio from -4 dB to 6.45 dB and outperforming existing deep learning models.
Why the study?
ECG recordings are often subject to various noises that can limit clinical evaluation, and existing models face inadequacies in learning long sequence time-series features.
Answers are grounded in this paper and cite their sources.
A novel Transformer-based CNN framework (APtrans-CNN) effectively denoises ECG signals, improving signal quality and downstream diagnostic accuracy.
The electrocardiogram (ECG) is a widely used diagnostic tool for cardiovascular diseases. However, ECG recording is often subject to various noises, which can limit its clinical evaluation. To address this issue, we propose a novel Transformer-based convolutional neural network framework with adaptively parametric ReLU (APtrans-CNN) for ECG signal denoising. The proposed APtrans-CNN architecture combines the strengths of transformers in global feature learning and CNNs in local feature learning to address the inadequacy of learning with long sequence time-series features. By fully exploiting the global features of ECG signals, our framework can effectively extract critical information that is necessary for signal denoising. We also introduce an adaptively parametric ReLU that can assign a value to the negative information contained in the ECG signal, thereby overcoming the limitation of ReLU to retain negative information. Additionally, we introduce a dynamic feature aggregation module that enables automatic learning and retention of valuable features while discarding useless noise information. Results obtained from two datasets demonstrate that our proposed APtrans-CNN can accurately extract pure ECG signals from noisy datasets and is adaptable to various applications. Specifically, when the input consists of ECG signals with a signal-to-noise ratio (SNR) of -4 dB, APtrans-CNN successfully increases the SNR to more than 6 dB, resulting in the diagnostic model's accuracy exceeding 96%.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2024) studied ECG signal noise (Arrhythmia and Atrial Fibrillation) (n=72). APtrans-CNN vs. Existing denoising methods (e.g., DWT, CNN, LSTM, IMUnet) was evaluated on Signal-to-noise ratio (SNR) output at -4 dB input noise (Arrhythmia database). The APtrans-CNN framework effectively denoised highly corrupted ECG signals, increasing the signal-to-noise ratio from -4 dB to 6.45 dB and outperforming existing deep learning models.
Synapse has enriched 10 related papers. Consider them for comparative context: